Dimensions

Width 115 mm
Height 130 mm
Depth 152.5 mm

Back to top

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2

Back to top

Input data

Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 85 V AC ... 264 V AC (Derating < 90 V AC: 2,5 %/V)
Dielectric strength maximum 300 V AC
AC frequency range 45 Hz ... 65 Hz
Discharge current to PE < 3.5 mA
Current consumption 4.6 A (120 V AC)
  2.4 A (230 V AC)
Nominal power consumption 533 VA
Inrush surge current < 15 A
Mains buffering > 13 ms (120 V AC)
  > 13 ms (230 V AC)
Input fuse 10 A (slow-blow, internal)
Choice of suitable circuit breakers 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.99
Type of protection Transient surge protection
Protective circuit/component Varistor

Back to top

Output data

Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage (USet) 22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 20 A (UOUT = 24 V DC)
Derating 55 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series yes
Feedback resistance 35 V DC
Protection against surge voltage on the output < 35 V DC
Max. capacitive load Unlimited
Active current limitation Approx. 25 A (for short-circuit)
Control deviation < 1 % (change in load, static 10 % ... 90 %)
  < 2 % (change in load, dynamic 10 % ... 90 %)
  < 0.1 % (change in input voltage ±10 %)
Residual ripple < 10 mVPP
Output power 480 W
Typical response time < 1 s
Peak switching voltages nominal load < 80 mVPP
Maximum power dissipation in no-load condition 4 W
Power loss nominal load max. 46 W

Back to top

General

Net weight 2.2 kg
Operating voltage display Green LED
Efficiency 91 % (for 230 V AC and nominal values)
Insulation voltage input/output 4 kV AC (type test)
  2 kV AC (routine test)
Insulation voltage input / PE 2 kV AC (type test)
  2 kV AC (routine test)
Insulation voltage output / PE 500 V DC (type test)
Protection class I (with PE connection)
Degree of protection IP20
MTBF (IEC 61709, SN 29500) > 915000 h
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm, vertically 50 mm

Back to top

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Stripping length 9 mm
Screw thread M2,5

Back to top

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.5 mm²
Conductor cross section solid max. 6 mm²
Conductor cross section flexible min. 0.5 mm²
Conductor cross section flexible max. 4 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 10
Stripping length 14 mm
Screw thread M3

Back to top

Signaling

Status display "DC OK" LED green
Note on status display UOUT > 21.5 V: LED lights up

Back to top

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise immunity EN 61000-6-2:2005
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Contact discharge 4 kV (Test Level 2)
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m
Frequency range 1.4 GHz ... 2 GHz
Test field strength 3 V/m
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
  EN 61000-6-3
  EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Standards/regulations EN 61000-4-11
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage EN 60950-1 (SELV)
  EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Limitation of mains harmonic currents EN 61000-3-2
UL approvals UL/C-UL listed UL 508
  UL/C-UL Recognized UL 60950-1
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
  15 Hz ... 150 Hz, 2.3g, 90 min.