TRIO-UPS/1AC/24DC/ 5-2866611
مدل: 2866611
شرح: منبع تغذیه UPS فونیکس کنتاکت
 

Dimensions

Width 60 mm
Height 130 mm
Depth 118 mm

Back to top

 

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Max. permissible relative humidity (operation) 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2

Back to top

 

Input data

Nominal input voltage range 100 V AC ... 240 V AC
AC input voltage range 85 V AC ... 264 V AC (Derating < 90 V AC: 2.5%V)
Input voltage range DC 100 V DC ... 350 V DC (UL508: 100 ... 250 V)
Buffer time adjustable: 0.5 min; 1 min; 2 min; 3 min; 5 min; 10 min; 15 min; 20 min; PC-Mode
Current consumption 1.1 A (230 V AC, maximum)
  1.8 A (120 V AC, maximum)
Inrush current limiting/I²t < 1.3 A2s
Mains buffering see diagram
Typical response time 150 ms (230 V AC)
  200 ms (120 V AC)
Power factor (cos phi) approx. 0.5
Protective circuit Transient surge protection Varistor
Input fuse, integrated 6.3 A (slow-blow, internal)

Back to top

 

Output data

Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 22.5 V DC ... 29.5 V DC (Network operation; in the buffer mode, dependent on the battery voltage of 27.9 V DC ... 19.2 V DC)
Nominal output current (IN) 5 A (-25 °C ... 55 °C)
Derating 55 °C ... 70 °C (2.5%/K)
Output current limit max. 6 A (Mains operation)
Control deviation < 1 % (change in load, static 10 % ... 90 %)
Efficiency > 88 % (230 V AC, network operation)
  > 86 % (120 V AC, network operation)
  > 86 % (Battery operation)
Residual ripple < 10 mVPP
Peak switching voltages nominal load < 25 mVPP
Connection in parallel Yes, 2
Surge protection against internal surge voltages Yes, < 35 V DC
Feedback resistance 35 V DC

Back to top

 

General

IQ technology no
Net weight 1.1 kg
Memory medium External, battery 1.3 Ah / 3.4 Ah / 7.2 Ah / 12 Ah
Operating mode  
Insulation voltage input/output 4 kV (type test)
  2 kV (routine test)
Protection class I
MTBF (IEC 61709, SN 29500)  
  > 596000 h (40 °C)
   
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm, vertically 50 mm

Back to top

 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3

Back to top

 

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 8 mm
Screw thread M3

Back to top

 

Connection data for signaling

Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M3

Back to top

 

Charging process

Charge characteristic curve I/U characteristic curve
Battery presence check/time interval 60 s
Charge current 0.2 A ... 1.5 A (Default 1.0 A)
End-of-charge voltage 25 V DC ... 30 V DC (Default 27.6 V DC)
Temperature compensation 0 mV/K ... 200 mV/K (42 mV/K by default)
Quality check of battery 4 h ... 200 h (Default 12 h)
Deep discharge protection 18 V DC ... 21 V DC (Default 19.2 V DC)
Alarm signaling threshold 18 V DC ... 30 V DC (Default 20.4 V DC)

Back to top

 

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission EN 55011 (EN 55022)
Noise immunity EN 61000-6-2:2005
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
Contact discharge 6 kV
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 2 GHz
Test field strength 10 V/m
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal 2 kV (Level 3 - asymmetrical)
  1 kV (Level 3 - symmetrical)
Standards/regulations EN 61000-6-3
  EN 61000-4-6
Frequency range 10 kHz ... 80 MHz
Voltage 10 V
Standards/regulations EN 61000-4-11
Low Voltage Directive Conformance with LV directive 2006/95/EC
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage EN 60950-1 (SELV)
  EN 60204 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
Standard – Limitation of mains harmonic currents EN 61000-3-2
Shipbuilding approval DNV GL (EMC B)
UL approvals UL/C-UL listed UL 508
  UL/C-UL Recognized UL 60950-1
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
  15 Hz ... 150 Hz, 2.3g, 90 min.
Rail applications EN 50121-4

Back to top

 

Environmental Product Compliance

China RoHS Environmentally Friendly Use Period = 25;
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”