QUINT4-PS/1AC/24DC/10 - 2904601
مدل: 2904601
شرح: منبع تغذیه 10Aفونیکس کنتاکت
 

Dimensions

Width 50 mm
Height 130 mm
Depth 125 mm
Width with alternative assembly 122 mm
Height with alternative assembly 130 mm
Depth with alternative assembly 53 mm

Back to top

 

Ambient conditions

Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 5000 m (> 2000 m, observe derating)

Back to top

 

Input data

Nominal input voltage range 100 V AC ... 240 V AC
  110 V DC ... 250 V DC
Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
  110 V DC ... 250 V DC -18 % ... +40 %
Dielectric strength maximum 300 V AC 60 s
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Discharge current to PE < 3.5 mA
Current consumption 3.4 A (100 V AC)
  2.8 A (120 V AC)
  1.5 A (230 V AC)
  1.5 A (240 V AC)
Nominal power consumption 274 VA
Inrush surge current typ. 18 A (at 25 °C)
Mains buffering ≥ 35 ms (120 V AC)
  ≥ 35 ms (230 V AC)
Input fuse 8 A (slow-blow, internal)
Choice of suitable circuit breakers 10 A ... 16 A (Characteristic B, C, D, K or comparable)
Type of protection Transient surge protection
Protective circuit/component Varistor, gas-filled surge arrester

Back to top

 

Output data

Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN) 10 A
Static Boost (IStat.Boost) 12.5 A
Dynamic Boost (IDyn.Boost) 20 A (5 s)
Selective Fuse Breaking (ISFB) 60 A (15 ms)
Derating > 60 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series yes
Feedback resistance ≤ 35 V DC
Protection against surge voltage on the output ≤ 32 V DC
Control deviation < 0.5 % (Static load change 10 % ... 90 %)
  < 4 % (Dynamic load change 10 % ... 90 %, (10 Hz))
  < 0.25 % (change in input voltage ±10 %)
Residual ripple < 80 mVPP (with nominal values)
Output power 240 W
Typical response time 300 ms (from SLEEP MODE)
Maximum power dissipation in no-load condition < 3 W (120 V AC)
  < 3 W (230 V AC)
Power loss nominal load max. < 20 W (120 V AC)
  < 17 W (230 V AC)

Back to top

 

General

Net weight 0.9 kg
Efficiency typ. 92.5 % (120 V AC)
  typ. 93.4 % (230 V AC)
Insulation voltage input/output 4 kV AC (type test)
  2 kV AC (routine test)
Insulation voltage input / PE 3.5 kV AC (type test)
  2.4 kV AC (routine test)
Insulation voltage output / PE 0.5 kV DC (type test)
  0.5 kV DC (routine test)
Protection class I
Degree of protection IP20
MTBF (IEC 61709, SN 29500) > 1250000 h (25 °C)
  > 783000 h (40 °C)
  > 377000 h (60 °C)
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Back to top

 

Connection data, input

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 30
Conductor cross section AWG max. 12
Stripping length 6.5 mm

Back to top

 

Connection data, output

Connection method Screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 30
Conductor cross section AWG max. 12
Stripping length 6.5 mm

Back to top

 

Connection data for signaling

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm

Back to top

 

Standards and Regulations

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Noise emission Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise immunity Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
Standards/regulations EN 61000-4-2
Contact discharge 4 kV (Test Level 2)
Standards/regulations EN 61000-4-3
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1.4 GHz ... 2 GHz
Test field strength 3 V/m (Test Level 2)
Standards/regulations EN 61000-4-4
Comments Criterion B
Standards/regulations EN 61000-4-5
Signal 0.5 kV (Test Level 1 - asymmetrical)
Standards/regulations EN 61000-4-6
Frequency range 0.15 MHz ... 80 MHz
Voltage 10 V (Test Level 3)
Conducted noise emission EN 55016 EN 61000-6-4 (Class A)
Standards/regulations EN 61000-4-8
  EN 61000-4-11
  EN 61000-4-9
  EN 61000-4-12
  EN 61000-4-16
  EN 61000-4-18
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV)
Standard - power supply devices for low voltage with DC output EN 61204-3
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 60950-1 (SELV)
  EN 60204-1 (PELV)
Standard - Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
EMC requirements, power plant IEC 61850-3
  EN 61000-6-5
Shipbuilding approval DNV GL, PRS, BV, LR, ABS
UL approvals UL Listed UL 508
  UL/C-UL Recognized UL 60950-1
  UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706; EN 61000-4-11
Rail applications EN 50121-3-2
Overvoltage category (EN 60950-1) II
Overvoltage category (EN 61010-1) II
Overvoltage category (EN 62477-1) III

Back to top

 

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
  For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”