فن تابلویی ریتال 3241100

توضیحات

فن و فیلتر با جریان 230m3/hrs ولتاژ 230V ابعاد 255mm*255mm
Fan&Filter-230m/h-230V-25*25cm

3241.100
Fan-and-filter units with diagonal fan technology have superior pressure stability and ensure a more constant air throughput. The diagonal direction of outflow ensures more even heat dissipation from the enclosure.
Colour
RAL 7035
Supply includes
Complete unit ready to install, including filter mat
Fan
Diagonal, shaded pole motor
Air throughput (unimpeded air flow)
Air throughput at 50 Hz: 230 m³/h
Air throughput at 60 Hz: 250 m³/h
Air throughput with outlet filter including standard filter mat (quantity x order number)
1 x 3240200: 183/205 m³/h
2 x 3240200: 203/220 m³/h
1 x 3243200: 203/230 m³/h
Rated operating voltage
230 V, 1~, 50 Hz/60 Hz
Rated current max.
At 50 Hz: 0.26 A
At 60 Hz: 0.24 A
Power consumption Pel
At 50 Hz: 40 W
At 60 Hz: 42 W
Dimensions
Width: 255 mm
Height: 255 mm
Installation dimensions
Build-up depth for components max: 25 mm
Installation depth: 107 mm
Mounting cut-out
Cut-out width: 224 mm
Cut-out height: 224 mm
Note
With the fan-and-filter unit 3237.XXX, electrical connection is made via two single wires (length approx. 300 mm) on the unit, for all other fan-and-filter units, a screwless spring terminal is used
IP protection category to IEC 60 529
IP protection category to IEC 60 529: IP 54
with standard filter and additional fine filter mat: IP 55
with standard filter and hose-proof hood: IP 56
Protection category NEMA
Standard: Type 12
with standard filter and additional fine filter mat: Type 12
with standard filter and hose-proof hood: Type 3, 3R, 4, 4X
Pre-fuse
Miniature circuit-breaker/fuse: 4 A
Service life of fans (L10, 40 °C)
At 50 Hz: 61,000 h
At 60 Hz: 60,000 h
Operating temperature range
-30 °C…55 °C
Storage temperature range
-30 °C…70 °C
Noise level
At 50 Hz: 54 dB(A)
At 60 Hz: 56 dB(A)
Weight/pack
2.24 kg
Packs of
1 pc(s).
Customs tariff number
84145915
EAN
4028177651982
ETIM 7.0
EC000320
ECLASS 8.0
27180716
Product description
SK fan and filter units TopTherm, 230/250 m³/h, 230 V, 1~, 50/60 Hz, WHD: 255 x 255 x 25 mm